12
13 = 1. Overview =
14
15
16 AIS is a video photo recognition sensor, the sensor can be used in electricity meters, gas meters, water meters, pressure gauges and other types of meters. Accurately identify the number of the current dial or upload the picture of the current dial for comparison, which can replace people to go to the door to read the meter, and is more accurate and energy-saving than the meter. The first thing to do is to fix the AIS sensor, the end direction needs to be aligned with the object that needs to be identified, you can check whether the object all appears in the lens range through the upper computer, and then calibrate, Chapter 2 will explain the calibration method of different tables. 
17
18
19 = 2. Calibrate Digits Readings =
20
21
22 According to the requirements to upgrade the firmware to correct the reading, respectively:[[Digital wheel dial firmware>>url:https://www.dropbox.com/scl/fi/nxa0nw0k2qhbpcxzfsz03/Digital-table-wheel-firmware.rar?rlkey=u9wqmilfwu899fhc9i2jfcwou&st=ftsl46f5&dl=0]],[[Pointer dial firmware>>url:https://www.dropbox.com/scl/fi/y03feisk7ztq1ey6pmhqb/Pointer-dial-firmware.rar?rlkey=knlx67m1g26xukrthcum1kk23&st=5m196s89&dl=0]].
23
24 Firmware upgrade Reference:[[Update Firmware for the AI Sensors>>http://wiki.dragino.com/xwiki/bin/view/Main/Update%20Firmware%20for%20AI%20Sensor/]].
25
26
27 == 2.1 Calibrate a Water Meter ==
28
29 === 2.1.1 Introduce ===
30
31
32 This water meter is designed in accordance with the Chinese standard for drinking cold water meters and hot water meters, GB/T 778.1-2007. It features five dial numbers for measurement accuracy.
33
34
35 === 2.1.2 Fix Sensor to a Water Meter ===
36
37
38 The assembly necessitates the use of two screws, two spacers, and this specific device.
39
40 Additionally, there are AIS Sensors available along with AUC USB TTL adapters for AIS Sensors.
41
42 The fixture below is just a demo, user might adjust it with their water meter. Here is the STEP file for the fixture as below: [[Water Meter Fixture Demo>>https://www.dropbox.com/scl/fo/p1ykgysrv8p454swsh4zj/AHCYr5pcOM0WNad4fT1sf_I?rlkey=7x964q1tuvh0ezbhgxb9b2zqg&st=wxxq87t3&dl=0]].
43
44 [[image:image-20240428163842-3.png||height="425" width="609"]] [[image:image-20240428155254-1.png||height="424" width="358"]]
45
46 The procedure is as follows:
47
48 ~1. Secure back of the AIS sensor  onto the small board and adjust its position according to your requirements. You may use two additional screws for fixation or utilize 3M double-sided adhesive for attachment.
49
50 [[image:image-20240428165320-4.gif]]
51
52
53 2. Proceed by fastening the device using the previously prepared screws and gaskets.
54
55 [[image:image-20240428165354-5.gif]]
56
57
58 3. Finally, nestle the device onto your water meter, ensuring that it can be adjusted to meet your specific needs while guaranteeing that the camera is directed towards the digital wheel face.
59
60 [[image:image-20240428165412-6.gif]].
61
62
63 The AI Sensors and AUC USB TTL Adapter for AIS Sensors are connected and then connected to the PC.
64
65 [[image:image-20240428165634-7.gif]][[image:image-20240428165645-8.jpeg||height="332" width="443"]]
66
67
68 === 2.1.3 Calibration ===
69
70
71 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
72
73 For example, Select the corresponding serial port number, here 14.
74
75 (% class="box warningmessage" %)
76 (((
77 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
78 )))
79
80 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]]
81
82 (% title="Click and drag to resize" %)​
83
84 Next, select a Baud rate of **921600** and click on **"start"**. Then, click on **"show full image" **to display the camera screen.
85
86 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​(% aria-label="image-20240419175103-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175103-7.png||data-widget="image" height="489" width="632"]]
87
88 (% title="Click and drag to resize" %)​
89
90 Click **"enable Raw" **and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
91
92 (% aria-label="image-20240419175324-8.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-8.png||data-widget="image" height="637" width="911"]](% title="Click and drag to resize" %)​
93
94 (% aria-label="image-20240419175324-9.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-9.png||data-widget="image" height="348" width="913"]](% title="Click and drag to resize" %)​
95
96 This water meter has only five fields, and the coordinates of the digital roulette wheel are shown in the figure.
97
98 If your device's digital scroll wheel dial does not match these five fields, you can try the other field dial coordinate dot plots in 2.4.
99
100 (% aria-label="1713573839396-314.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713573839396-314.png||data-widget="image" height="198" width="649"]](% title="Click and drag to resize" %)​
101
102 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
103
104 (% aria-label="1713574859715-722.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713574859715-722.png||data-widget="image" height="481" width="576"]]
105
106 (% title="Click and drag to resize" %)​
107
108 Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
109
110 The "Long dial" option is the long hand dial.
111
112 The "Short dial" option is the short pointer and digital wheel dial.
113
114 The "Digit wheel" option is the digital wheel dial.
115
116 Now we are calibrating the digital wheel face of the water meter. Here we select "digit wheel".
117
118 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]](% title="Click and drag to resize" %)​
119
120 1:Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
121
122 2: Fill in the number of number wheel on their dial,fi;
123
124 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
125
126 4: Preview whether the setting of their coordinates is accurate;
127
128 5: Click to write all configuration to AIS;
129
130 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
131
132 (% aria-label="1713576930301-479.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576930301-479.png||data-widget="image"]](% title="Click and drag to resize" %)​
133
134 The effect can be previewed by clicking the "Preview correction" button as shown below.
135
136 (% aria-label="1713577029535-253.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713577029535-253.png||data-widget="image" height="748" width="1069"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
137
138
139 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
140
141 (% aria-label="1713577072196-132.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713577072196-132.png||data-widget="image" height="751" width="1073"]]
142
143 (% title="Click and drag to resize" %)​
144
145 == 2.2 Calibration Power Meter ==
146
147 === 2.2.1 Introduce ===
148
149
150 This power meter is designed in accordance with the Chinese standard for Electricity metering equipment, GB/T 17215.321-2008. It features six dial numbers for measurement accuracy.
151
152
153 === 2.2.2 Fix Sensor to a Power Meter ===
154
155
156 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
157
158 [[image:image-20240429091325-1.png||height="706" width="535"]]
159
160
161 === 2.2.3 Calibration ===
162
163
164 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
165
166 For example, Select the corresponding serial port number, here 14.
167
168 (% class="box warningmessage" %)
169 (((
170 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
171 )))
172
173 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]]
174
175 (% title="Click and drag to resize" %)​
176
177 Next, select a Baud rate of **921600** and click on **"start"**. Then, click on **"show full image"** to display the camera screen.
178
179 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]][[image:image-20240420135207-3.png||height="485" width="706"]]
180
181
182 Click **"enable Raw"** and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
183
184 [[image:1713592384928-500.png||height="494" width="266"]][[image:image-20240420141955-4.png||height="492" width="782"]]
185
186 This power meter has only six fields, and the coordinates of the digital roulette wheel are shown in the figure.
187
188 If your device's digital scroll wheel dial does not match these six fields, you can try the other field dial coordinate dot plots in 2.4.
189
190 (% aria-label="image-20240420094632-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-13.png||data-widget="image" height="148" width="588"]]
191
192 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
193
194 [[image:image-20240420153316-11.png||height="569" width="755"]]
195
196
197 (% id="cke_bm_67462S" style="display:none" %) (%%)Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
198
199 The "Long dial" option is the long hand dial.
200
201 The "Short dial" option is the short pointer and digital wheel dial.
202
203 The "Digit wheel" option is the digital wheel dial.
204
205 Now we are calibrating the digital wheel face of the power meter. Here we select "digit wheel".
206
207 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]](% title="Click and drag to resize" %)​
208
209 1: Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
210
211 2: Fill in the number of number wheel on their dial,six;
212
213 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
214
215 4: Preview whether the setting of their coordinates is accurate;
216
217 5: Click to write all configuration to AIS;
218
219 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
220
221 [[image:image-20240420143939-6.png||height="408" width="886"]](% title="Click and drag to resize" %)​
222
223 The effect can be previewed by clicking the "Preview correction" button as shown below.
224
225 [[image:image-20240420144154-7.png||height="534" width="880"]]
226
227 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
228
229 [[image:1713595371004-125.png]]
230
231
232 == 2.3 Calibration Gas Meter ==
233
234 === 2.3.1 Introduce ===
235
236
237 This gas meter uses G2.5 membrane gas meter. It features eight dial numbers for measurement accuracy.
238
239
240 === 2.3.2 Fix Sensor to a Gas Meter ===
241
242
243 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
244
245 [[image:image-20240429092436-2.png||height="676" width="519"]]
246
247
248 === 2.3.3 Calibration ===
249
250
251 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
252
253 For example, Select the corresponding serial port number, here 14.
254
255 (% class="box warningmessage" %)
256 (((
257 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
258 )))
259
260 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
261
262 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
263
264 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]][[image:1713598021017-402.png]]
265
266 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
267
268 [[image:1713592384928-500.png||height="494" width="266"]][[image:1713598094208-496.png||height="494" width="790"]]
269
270 This gas meter has eight fields, and the coordinates of the digital roulette wheel are shown in the figure.
271
272 If your device's digital scroll wheel dial does not match these eight fields, you can try the other field dial coordinate dot plots in 2.4.
273
274 (% aria-label="image-20240420094632-15.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-15.png||data-widget="image" height="113" width="542"]]
275
276 (% id="cke_bm_196694S" style="display:none" %) (%%)The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
277
278 [[image:image-20240420153139-10.png||height="530" width="710"]]
279
280 (% id="cke_bm_67462S" style="display:none" %) (%%)Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
281
282 The "Long dial" option is the long hand dial.
283
284 The "Short dial" option is the short pointer and digital wheel dial.
285
286 The "Digit wheel" option is the digital wheel dial.
287
288 Now we are calibrating the digital wheel face of the gas meter. Here we select "digit wheel".
289
290 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]]
291
292 1: Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
293
294 2: Fill in the number of number wheel on their dial,eight;
295
296 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
297
298 4: Preview whether the setting of their coordinates is accurate;
299
300 5: Click to write all configuration to AIS;
301
302 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
303
304 [[image:image-20240420154023-12.png||height="436" width="942"]](% title="Click and drag to resize" %)​
305
306 The effect can be previewed by clicking the "Preview correction" button as shown below.
307
308 [[image:1713598855240-454.png]]
309
310 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
311
312 [[image:1714358288601-933.png]]
313
314
315 == 2.4 Digital wheel dial take point coordinate diagram ==
316
317
318 4  numbers:
319
320 (% aria-label="image-20240420094632-11.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-11.png||data-widget="image" height="134" width="410"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
321
322 5 numbers:
323
324 (% aria-label="image-20240420094632-12.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-12.png||data-widget="image" height="130" width="427"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
325
326 6 numbers:
327
328 (% aria-label="image-20240420094632-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-13.png||data-widget="image" height="112" width="444"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
329
330 7 numbers:
331
332 (% aria-label="image-20240420094632-14.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-14.png||data-widget="image" height="111" width="454"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
333
334 8 numbers:
335
336 (% aria-label="image-20240420094632-15.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-15.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]]
337
338 (% title="Click and drag to resize" %)​
339
340 == 2.5 Pressure Pointer Meter Calibration ==
341
342 === 2.5.1 Introduce ===
343
344
345 The pressure pointer meter of the example is 1.6MPa range
346
347
348 === 2.5.2 Fix Sensor to a Power Meter​ ===
349
350
351 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the pressure pointer meter.
352
353 [[image:image-20240516163229-1.jpeg||height="595" width="446"]]
354
355
356 === 2.5.3 Calibration ===
357
358
359 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
360
361 For example, Select the corresponding serial port number, here 14.
362
363 (% class="box warningmessage" %)
364 (((
365 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
366 )))
367
368 [[image:image-20240516163338-2.png||height="455" width="733"]]
369
370
371 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
372
373 [[image:image-20240516163423-3.png]]
374
375
376 Click **"enable Raw"** and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
377
378 [[image:image-20240516163501-4.png||height="482" width="694"]]
379
380 [[image:image-20240516163528-5.png||height="336" width="696"]]
381
382
383 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the pressure pointer meter, as shown below.
384
385 The coordinates of the pressure pointer table are located as shown below.
386
387 1 is the start point, 2 is the center point, and 3 is the end point.
388
389 The (x,y) coordinate on the image is located at the bottom left corner.
390
391 [[image:image-20240516163622-6.png||height="648" width="666"]]
392
393
394 Click on the ROI settingbutton in himax_amr_pc_tool. it will have three optionsThe long dial" option is a long dial dial.The "short dial" option is a short pointer and a number of wheel dial.The digit wheeler option is the digital wheel dial.Now the calibration is the pressure pointer table, which is long dialon."
395
396 [[image:image-20240516163910-7.png]]
397
398
399 Fill in the values of the coordinates you just got, and it's best to get one and write one
400
401 1 Coordinates of the starting point of the scale
402
403 2 Coordinates of the center point of the dial
404
405 3 Coordinates of the end of the scale
406
407 4 Starting scale value
408
409 5 End point scale value *100
410
411 After filling in the data, click "send ROI" to save the Settings and click "Cancel" to exit.
412
413 [[image:image-20240516164128-13.png||height="410" width="889"]]
414
415
416 After the calibration process is completed, The AIS cannot move thereafter to avoid misreading.
417
418 it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
419
420 [[image:image-20240516164153-14.png]]
421
422
423 = (% title="Click and drag to resize" %)3. Get Sensor Data(%%) =
424
425 == (% title="Click and drag to resize" %)3.1 Get Image and show in PC(%%) ==
426
427
428 To get the AIS current image on the PC, you can  connect AIS to your PC with TTL to send commands through the serial port to obtain relevant data packets.
429
430
431 === (% style="color:inherit; font-family:inherit; font-size:23px" %)3.1.1 The image date are obtained by serial port(%%) ===
432
433
434 Select the corresponding baud rate and serial port number through the serial port tool, select HEX display and HEX send, and continuously receive data from the AIS Sensor
435
436 [[image:image-20240514161623-2.png||height="541" width="1439"]]
437
438 In the serial port to send data C0 5A 00 00 00 00 04, and then send C0 5A 00 00 00 00 09, AIS Sensor will send a real-time image of the data packet, and then stop sending. Start with FFD8 and put it in TXT file
439
440 [[image:image-20240514161658-3.png||height="544" width="1441"]]
441
442
443 === 3.1.2 Combined image ===
444
445
446 Once all the data has been uploaded to the TTN platform, the subsequent step involves concatenating each packet in sequential order and saving it into a new TXT file. It is important to note that the first 8 bytes of each packet should be removed before concatenation.
447
448 When you combine all the packets, you need to convert the data inside to binary. Here the conversion is demonstrated using the [[WinHex>>http://www.x-ways.net/winhex/index-m.html]] software.
449
450 Open WinHex to open the combined image data file.
451
452 [[image:1714467040612-103.png||height="134" width="649"]]
453
454
455 Click on the **edit** option to choose and **convert**.
456
457 [[image:1714467065723-178.png||height="349" width="762"]]
458
459
460 Choose the **Hex ASCII->Binary** option and then click OK.
461
462 [[image:1714467089355-837.png||height="366" width="336"]]
463
464
465 After the conversion is finished, click on **"File"** and choose **"Save As"**.
466
467 [[image:1714467112365-676.png]]
468
469
470 Save as **a.jpg file** and click OK to generate a JPG file.
471
472 [[image:1714467126476-110.png]]
473
474
475 Open the saved JPG file to display the image transmitted by the AIS Sensor through the serial port.
476
477 [[image:1714467134950-189.png]]