12
13 = 1. Overview =
14
15
16 AIS is a video photo recognition sensor, the sensor can be used in electricity meters, gas meters, water meters, pressure gauges and other types of meters. Accurately identify the number of the current dial or upload the picture of the current dial for comparison, which can replace people to go to the door to read the meter, and is more accurate and energy-saving than the meter. The first thing to do is to fix the AIS sensor, the end direction needs to be aligned with the object that needs to be identified, you can check whether the object all appears in the lens range through the upper computer, and then calibrate, Chapter 2 will explain the calibration method of different tables. 
17
18
19 = 2. Calibrate Digits Readings =
20
21
22 The factory default firmware of AIS Sensor is a digital wheel dial. It is recommended that the distance between the camera and the digital wheel dial be 3cm-7cm when installing AIS Sensor. Because the distance is too far, the camera's flash will not be able to illuminate the digital wheel dial to obtain readings.
23
24 If you are using a [[pointer type dial>>http://wiki.dragino.com/xwiki/bin/view/Main/AI%20Image%20Sensor%20Calibration/#H2.5PressurePointerMeterCalibration]], just adjust the camera to fully see the entire dial.
25
26 According to the requirements to upgrade the firmware to correct the reading, respectively:[[Digital wheel dial firmware>>url:https://www.dropbox.com/scl/fi/nxa0nw0k2qhbpcxzfsz03/Digital-table-wheel-firmware.rar?rlkey=u9wqmilfwu899fhc9i2jfcwou&st=ftsl46f5&dl=0]],[[Pointer dial firmware>>url:https://www.dropbox.com/scl/fi/y03feisk7ztq1ey6pmhqb/Pointer-dial-firmware.rar?rlkey=knlx67m1g26xukrthcum1kk23&st=5m196s89&dl=0]].
27
28 Firmware upgrade Reference:[[Update Firmware for the AI Sensors>>http://wiki.dragino.com/xwiki/bin/view/Main/Update%20Firmware%20for%20AI%20Sensor/]].
29
30
31 == 2.1 Calibrate a Water Meter ==
32
33 === 2.1.1 Introduce ===
34
35
36 This water meter is designed in accordance with the Chinese standard for drinking cold water meters and hot water meters, GB/T 778.1-2007. It features five dial numbers for measurement accuracy.
37
38
39 === 2.1.2 Fix Sensor to a Water Meter ===
40
41
42 The assembly necessitates the use of two screws, two spacers, and this specific device.
43
44 Additionally, there are AIS Sensors available along with AUC USB TTL adapters for AIS Sensors.
45
46 The fixture below is just a demo, user might adjust it with their water meter. Here is the STEP file for the fixture as below: [[Water Meter Fixture Demo>>https://www.dropbox.com/scl/fo/p1ykgysrv8p454swsh4zj/AHCYr5pcOM0WNad4fT1sf_I?rlkey=7x964q1tuvh0ezbhgxb9b2zqg&st=wxxq87t3&dl=0]].
47
48 [[image:image-20240428163842-3.png||height="425" width="609"]] [[image:image-20240428155254-1.png||height="424" width="358"]]
49
50 The procedure is as follows:
51
52 ~1. Secure back of the AIS sensor  onto the small board and adjust its position according to your requirements. You may use two additional screws for fixation or utilize 3M double-sided adhesive for attachment.
53
54 [[image:image-20240428165320-4.gif]]
55
56
57 2. Proceed by fastening the device using the previously prepared screws and gaskets.
58
59 [[image:image-20240428165354-5.gif]]
60
61
62 3. Finally, nestle the device onto your water meter, ensuring that it can be adjusted to meet your specific needs while guaranteeing that the camera is directed towards the digital wheel face.
63
64 [[image:image-20240428165412-6.gif]].
65
66
67 The AI Sensors and AUC USB TTL Adapter for AIS Sensors are connected and then connected to the PC.
68
69 [[image:image-20240428165634-7.gif]][[image:image-20240428165645-8.jpeg||height="332" width="443"]]
70
71
72 === 2.1.3 Calibration ===
73
74
75 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
76
77 For example, Select the corresponding serial port number, here 14.
78
79 (% class="box warningmessage" %)
80 (((
81 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
82 )))
83
84 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]]
85
86 (% title="Click and drag to resize" %)​
87
88 Next, select a Baud rate of **921600** and click on **"start"**. Then, click on **"show full image" **to display the camera screen.
89
90 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​(% aria-label="image-20240419175103-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175103-7.png||data-widget="image" height="489" width="632"]]
91
92 (% title="Click and drag to resize" %)​
93
94 Click **"enable Raw" **and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
95
96 (% aria-label="image-20240419175324-8.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-8.png||data-widget="image" height="637" width="911"]](% title="Click and drag to resize" %)​
97
98 (% aria-label="image-20240419175324-9.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-9.png||data-widget="image" height="348" width="913"]](% title="Click and drag to resize" %)​
99
100 This water meter has only five fields, and the coordinates of the digital roulette wheel are shown in the figure.
101
102 If your device's digital scroll wheel dial does not match these five fields, you can try the other field dial coordinate dot plots in 2.4.
103
104 (% aria-label="1713573839396-314.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713573839396-314.png||data-widget="image" height="198" width="649"]](% title="Click and drag to resize" %)​
105
106 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
107
108 (% aria-label="1713574859715-722.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713574859715-722.png||data-widget="image" height="481" width="576"]]
109
110 (% title="Click and drag to resize" %)​
111
112 Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
113
114 The "Long dial" option is the long hand dial.
115
116 The "Short dial" option is the short pointer and digital wheel dial.
117
118 The "Digit wheel" option is the digital wheel dial.
119
120 Now we are calibrating the digital wheel face of the water meter. Here we select "digit wheel".
121
122 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]](% title="Click and drag to resize" %)​
123
124 1:Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
125
126 2: Fill in the number of number wheel on their dial,fi;
127
128 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
129
130 4: Preview whether the setting of their coordinates is accurate;
131
132 5: Click to write all configuration to AIS;
133
134 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
135
136 (% aria-label="1713576930301-479.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576930301-479.png||data-widget="image"]](% title="Click and drag to resize" %)​
137
138 The effect can be previewed by clicking the "Preview correction" button as shown below.
139
140 (% aria-label="1713577029535-253.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713577029535-253.png||data-widget="image" height="748" width="1069"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
141
142
143 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
144
145 (% aria-label="1713577072196-132.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713577072196-132.png||data-widget="image" height="751" width="1073"]]
146
147 (% title="Click and drag to resize" %)​
148
149 == 2.2 Calibration Power Meter ==
150
151 === 2.2.1 Introduce ===
152
153
154 This power meter is designed in accordance with the Chinese standard for Electricity metering equipment, GB/T 17215.321-2008. It features six dial numbers for measurement accuracy.
155
156
157 === 2.2.2 Fix Sensor to a Power Meter ===
158
159
160 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
161
162 [[image:image-20240429091325-1.png||height="706" width="535"]]
163
164
165 === 2.2.3 Calibration ===
166
167
168 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
169
170 For example, Select the corresponding serial port number, here 14.
171
172 (% class="box warningmessage" %)
173 (((
174 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
175 )))
176
177 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]]
178
179 (% title="Click and drag to resize" %)​
180
181 Next, select a Baud rate of **921600** and click on **"start"**. Then, click on **"show full image"** to display the camera screen.
182
183 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]][[image:image-20240420135207-3.png||height="485" width="706"]]
184
185
186 Click **"enable Raw"** and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
187
188 [[image:1713592384928-500.png||height="494" width="266"]][[image:image-20240420141955-4.png||height="492" width="782"]]
189
190 This power meter has only six fields, and the coordinates of the digital roulette wheel are shown in the figure.
191
192 If your device's digital scroll wheel dial does not match these six fields, you can try the other field dial coordinate dot plots in 2.4.
193
194 (% aria-label="image-20240420094632-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-13.png||data-widget="image" height="148" width="588"]]
195
196 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
197
198 [[image:image-20240420153316-11.png||height="569" width="755"]]
199
200
201 (% id="cke_bm_67462S" style="display:none" %) (%%)Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
202
203 The "Long dial" option is the long hand dial.
204
205 The "Short dial" option is the short pointer and digital wheel dial.
206
207 The "Digit wheel" option is the digital wheel dial.
208
209 Now we are calibrating the digital wheel face of the power meter. Here we select "digit wheel".
210
211 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]](% title="Click and drag to resize" %)​
212
213 1: Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
214
215 2: Fill in the number of number wheel on their dial,six;
216
217 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
218
219 4: Preview whether the setting of their coordinates is accurate;
220
221 5: Click to write all configuration to AIS;
222
223 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
224
225 [[image:image-20240420143939-6.png||height="408" width="886"]](% title="Click and drag to resize" %)​
226
227 The effect can be previewed by clicking the "Preview correction" button as shown below.
228
229 [[image:image-20240420144154-7.png||height="534" width="880"]]
230
231 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
232
233 [[image:1713595371004-125.png]]
234
235
236 == 2.3 Calibration Gas Meter ==
237
238 === 2.3.1 Introduce ===
239
240
241 This gas meter uses G2.5 membrane gas meter. It features eight dial numbers for measurement accuracy.
242
243
244 === 2.3.2 Fix Sensor to a Gas Meter ===
245
246
247 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
248
249 [[image:image-20240429092436-2.png||height="676" width="519"]]
250
251
252 === 2.3.3 Calibration ===
253
254
255 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
256
257 For example, Select the corresponding serial port number, here 14.
258
259 (% class="box warningmessage" %)
260 (((
261 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
262 )))
263
264 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
265
266 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
267
268 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]][[image:1713598021017-402.png]]
269
270 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
271
272 [[image:1713592384928-500.png||height="494" width="266"]][[image:1713598094208-496.png||height="494" width="790"]]
273
274 This gas meter has eight fields, and the coordinates of the digital roulette wheel are shown in the figure.
275
276 If your device's digital scroll wheel dial does not match these eight fields, you can try the other field dial coordinate dot plots in 2.4.
277
278 (% aria-label="image-20240420094632-15.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-15.png||data-widget="image" height="113" width="542"]]
279
280 (% id="cke_bm_196694S" style="display:none" %) (%%)The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
281
282 [[image:image-20240420153139-10.png||height="530" width="710"]]
283
284 (% id="cke_bm_67462S" style="display:none" %) (%%)Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
285
286 The "Long dial" option is the long hand dial.
287
288 The "Short dial" option is the short pointer and digital wheel dial.
289
290 The "Digit wheel" option is the digital wheel dial.
291
292 Now we are calibrating the digital wheel face of the gas meter. Here we select "digit wheel".
293
294 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]]
295
296 1: Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
297
298 2: Fill in the number of number wheel on their dial,eight;
299
300 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
301
302 4: Preview whether the setting of their coordinates is accurate;
303
304 5: Click to write all configuration to AIS;
305
306 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
307
308 [[image:image-20240420154023-12.png||height="436" width="942"]](% title="Click and drag to resize" %)​
309
310 The effect can be previewed by clicking the "Preview correction" button as shown below.
311
312 [[image:1713598855240-454.png]]
313
314 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
315
316 [[image:1714358288601-933.png]]
317
318
319 == 2.4 Digital wheel dial take point coordinate diagram ==
320
321
322 4  numbers:
323
324 (% aria-label="image-20240420094632-11.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-11.png||data-widget="image" height="134" width="410"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
325
326 5 numbers:
327
328 (% aria-label="image-20240420094632-12.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-12.png||data-widget="image" height="130" width="427"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
329
330 6 numbers:
331
332 (% aria-label="image-20240420094632-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-13.png||data-widget="image" height="112" width="444"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
333
334 7 numbers:
335
336 (% aria-label="image-20240420094632-14.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-14.png||data-widget="image" height="111" width="454"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
337
338 8 numbers:
339
340 (% aria-label="image-20240420094632-15.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-15.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]]
341
342 (% title="Click and drag to resize" %)​
343
344 == 2.5 Pressure Pointer Meter Calibration ==
345
346 === 2.5.1 Introduce ===
347
348
349 The pressure pointer meter of the example is 1.6MPa range
350
351
352 === 2.5.2 Fix Sensor to a Power Meter​ ===
353
354
355 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the pressure pointer meter.
356
357 [[image:image-20240516163229-1.jpeg||height="595" width="446"]]
358
359
360 === 2.5.3 Calibration ===
361
362
363 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
364
365 For example, Select the corresponding serial port number, here 14.
366
367 (% class="box warningmessage" %)
368 (((
369 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
370 )))
371
372 [[image:image-20240516163338-2.png||height="455" width="733"]]
373
374
375 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
376
377 [[image:image-20240516163423-3.png]]
378
379
380 Click **"enable Raw"** and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
381
382 [[image:image-20240516163501-4.png||height="482" width="694"]]
383
384 [[image:image-20240516163528-5.png||height="336" width="696"]]
385
386
387 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the pressure pointer meter, as shown below.
388
389 The coordinates of the pressure pointer table are located as shown below.
390
391 1 is the start point, 2 is the center point, and 3 is the end point.
392
393 The (x,y) coordinate on the image is located at the bottom left corner.
394
395 [[image:image-20240516163622-6.png||height="648" width="666"]]
396
397
398 Click on the ROI settingbutton in himax_amr_pc_tool. it will have three optionsThe long dial" option is a long dial dial.The "short dial" option is a short pointer and a number of wheel dial.The digit wheeler option is the digital wheel dial.Now the calibration is the pressure pointer table, which is long dialon."
399
400 [[image:image-20240516163910-7.png]]
401
402
403 Fill in the values of the coordinates you just got, and it's best to get one and write one
404
405 1 Coordinates of the starting point of the scale
406
407 2 Coordinates of the center point of the dial
408
409 3 Coordinates of the end of the scale
410
411 4 Starting scale value
412
413 5 End point scale value *100
414
415 After filling in the data, click "send ROI" to save the Settings and click "Cancel" to exit.
416
417 [[image:image-20240516164128-13.png||height="410" width="889"]]
418
419
420 After the calibration process is completed, The AIS cannot move thereafter to avoid misreading.
421
422 it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
423
424 [[image:image-20240516164153-14.png]]
425
426
427 = (% title="Click and drag to resize" %)3. Get Sensor Data(%%) =
428
429 == (% title="Click and drag to resize" %)3.1 Get Image and show in PC(%%) ==
430
431
432 To get the AIS current image on the PC, you can  connect AIS to your PC with TTL to send commands through the serial port to obtain relevant data packets.
433
434
435 === (% style="color:inherit; font-family:inherit; font-size:23px" %)3.1.1 The image date are obtained by serial port(%%) ===
436
437
438 Select the corresponding baud rate and serial port number through the serial port tool, select HEX display and HEX send, and continuously receive data from the AIS Sensor
439
440 [[image:image-20240514161623-2.png||height="541" width="1439"]]
441
442 In the serial port to send data C0 5A 00 00 00 00 04, and then send C0 5A 00 00 00 00 09, AIS Sensor will send a real-time image of the data packet, and then stop sending. Start with FFD8 and put it in TXT file
443
444 [[image:image-20240514161658-3.png||height="544" width="1441"]]
445
446
447 === 3.1.2 Combined image ===
448
449
450 Once all the data has been uploaded to the TTN platform, the subsequent step involves concatenating each packet in sequential order and saving it into a new TXT file. It is important to note that the first 8 bytes of each packet should be removed before concatenation.
451
452 When you combine all the packets, you need to convert the data inside to binary. Here the conversion is demonstrated using the [[WinHex>>http://www.x-ways.net/winhex/index-m.html]] software.
453
454 Open WinHex to open the combined image data file.
455
456 [[image:1714467040612-103.png||height="134" width="649"]]
457
458
459 Click on the **edit** option to choose and **convert**.
460
461 [[image:1714467065723-178.png||height="349" width="762"]]
462
463
464 Choose the **Hex ASCII->Binary** option and then click OK.
465
466 [[image:1714467089355-837.png||height="366" width="336"]]
467
468
469 After the conversion is finished, click on **"File"** and choose **"Save As"**.
470
471 [[image:1714467112365-676.png]]
472
473
474 Save as **a.jpg file** and click OK to generate a JPG file.
475
476 [[image:1714467126476-110.png]]
477
478
479 Open the saved JPG file to display the image transmitted by the AIS Sensor through the serial port.
480